Three Phase ISO9001-2008 AC Motor

Three Phase ISO9001-2008 AC Motor

CZPT-2008 Motor

IP54 motor&comma AC motor

Definition&colon

one&time period Y2 Collection Cast of Iron 3 Period Induction Motor is specially created for CZPTpean industry&comma whose terminal box is found on the top of motor&period of time They are completely enclosed and supporter-cooling created&time period They are newly created in conformity with the related specifications &sol principles of IEC&DIN42673 expectations&period of time
They benefit of substantial effectiveness&comma long operating life&comma strength conserving&comma substantial starting up torque&comma lower sound&comma small vibration&comma large breakaway torque&comma reputable procedure performance&comma effortless & hassle-free servicing&period of time Repairing measurement and electrical power quality entirely conform to IEC specifications&period
2&interval Y2 collection three section asynchronous electric powered motors are widely used in numerous fields&comma such as machine equipment&comma pumps&comma followers&comma transportation machinery&comma mixer&comma agriculture machinery&comma meals equipment&comma agitator&comma air compressor and so on&period of time We also can provide aluminum housing kind for body size under the common of IEC132&interval
For the Connection Model of Y2 motor&comma remember to refer to the Name Plate on the motor &lparThe Y Relationship is adopted by motors’ Output equivalent or underneath 3kW&semi The Delta-Link is adopted by motors’ Output previously mentioned 4kW&rpar&time period
three&period of time Y2 Motor can be equipped with PTC&period of time
–For motor of frame size 160MM and above can be geared up with re-greasing system&time period

Specs&colon

Ambient Temperature&colon -15° C~40° C
Altitude&colon Not exceed one thousand Meter
Rated Voltage&colon 380V or any voltage amongst 220-1140V
Rated Frequency&colon 50Hz&sol60Hz
Defense Class&colon IP44&comma IP54&comma IP55
Insulation Course&colon B&solF
Cooling Approach&colon IC0141
Working Obligation&colon S1&lparContinuous&rpar
Humidity&colon Reduced than ninety&percnt
Relationship&colon CZPT-link for up to 3kW&semi Delta-connection for 4kW and previously mentioned

Ordering Informations&colon

one&time period Please indicate the motor sort&comma rated output&comma rated voltage&comma rated frequency&comma synchronous speed&comma Explosion evidence Mark&comma mounting kind&comma rotation direction&lparview from the shaft extension side&rparUse of the environment&lparindoor or outside&rparIf the consumer havn’t position out the rotation and environment&comma normailly we feel is CW roration and used indoor&interval
2&period of time When consumer have special requirments&comma For example&colon Dispose the stator&comma bearing explosion evidence and bearing temperature sensors&comma place heater&comma Plateau use&comma specical frequency&comma mounting size adjust&comma special output&comma the person have to&comma get can be affirm soon after signing the specialized arrangement with engneering division&period of time
three&interval This variety of motor can also be produced into Variable-Frequency motors&comma the assortment of frequency of which is -100HZ&comma the output and overall dimensions need to be validate separately&period

   
one&periodY2 collection ac induction motor mounting specifics&colon

Schematic diagram
 
       
mounting kind
 
B3
 
B35
 
B5
 
V1
 
mounting Discribtion
 
body with feet&commaend-shield CZPT flange
 
body with feet&commaend-defend with flange
 
frame CZPT toes&commaend-protect with flange
 
body CZPT feet&commaend-shield with flange
 
Appropriate frame
 
H63-355
 
H63-355
 
H63-280
 
H180-355
 

Y2 sequence motors are absolutely enclosed enthusiast cold&lparTEFC&rpar&time period

2&periodbearing variety-table two
desk 2

     
Horizontal
 
vertical
 
motor
body
 
DE side
 
N-DE aspect
 
DE side
 
N-DE side
 
63
 
6201-2RZ&solZ2
 
6201-2RZ&solZ2
 
6201-2RZ&solZ2
 
6201-2RZ&solZ2
 
seventy one
 
6202-2RZ&solZ2
 
6202-2RZ&solZ2
 
6202-2RZ&solZ2
 
6202-2RZ&solZ2
 
80
 
6204-2RZ&solZ2
 
6204-2RZ&solZ2
 
6204-2RZ&solZ2
 
6204-2RZ&solZ2
 
ninety
 
6205-2RZ&solZ2
 
6205-2RZ&solZ2
 
6205-2RZ&solZ2
 
6205-2RZ&solZ2
 
100
 
6206-2RZ&solZ2
 
6206-2RZ&solZ2
 
6206-2RZ&solZ2
 
6206-2RZ&solZ2
 
112
 
6206-2RZ&solZ2
 
6206-2RZ&solZ2
 
6206-2RZ&solZ2
 
6206-2RZ&solZ2
 
132
 
6208-2RZ&solZ2
 
6208-2RZ&solZ2
 
6208-2RZ&solZ2
 
6208-2RZ&solZ2
 
160
 
6209-2RZ&solZ2
 
6209-2RZ&solZ2
 
6209-2RZ&solZ2
 
6209-2RZ&solZ2
 
one hundred eighty
 
6211&solZ2
 
6211&solZ2
 
6211&solZ2
 
6211&solZ2
 
two hundred
 
6312&solZ2
 
6312&solZ2
 
6312&solZ2
 
6312&solZ2
 
225&lpar2P&rpar
 
6312&solZ2
 
6312&solZ2
 
6312&solZ2
 
6312&solZ2
 
225&lpar4-8P&rpar
 
6313&solZ2
 
6212&solZ2
 
6313&solZ2
 
6312&solZ2
 
250&lpar2P&rpar
 
6313&solZ2&solZ2
 
6313&solZ1
 
6313&solZ2
 
6313&solZ1
 
250&lpar4-8P&rpar
 
6314&solZ1
 
6213&solZ1
 
6314&solZ1
 
6313&solZ1
 
280&lpar2P&rpar
 
6314&solZ1
 
6313&solZ1
 
6314&solZ1
 
6313&solZ1
 
280&lpar4P&rpar
 
6317&solZ1
 
6313&solZ1
 
6317&solZ1
 
6313&solZ1
 
315&lpar2P&rpar
 
6317&solZ1
 
6317&solZ1
 
6317&solZ1
 
6317&solZ1
 
315&lpar4-8P&rpar
 
NU319
 
6319&solZ1
 
NU319
 
6319&solZ1
 
355&lpar2P&rpar
 
6319&solZ1
 
6319&solZ1
 
6319&solZ1
 
6319&solZ1
 
355&lpar4-8P&rpar
 
NU322
 
6322&solZ1
 
NU322&solZ1
 
6322&solZ1
 

 
 

 
 

 
 

 

 

Three Phase ISO9001-2008 AC Motor