Motor Management Centre Protective Swap KB0(RDCPS2)
Overview
RDCPS2 management and protecting switch is largely applied to reduced-voltage power distribution and motor manage and security circuits. Rated working voltage 690V and below, AC fifty/60Hz, rated operating recent .15A ~ 125A.
RDCPS2 is a large-end item with optimized construction, compact, vitality-conserving, environmentally environmental welcoming resources, effortless set up and procedure intelligent digital controlsystem, reputable security, and interaction interface, it safe computerized handle techniques and distant handle systems.
RDCPS2 is a all-in-one particular switching device with circuit overload, quick circuit defense functions, large breaking capacity it is in a position to producing and breaking the load, lengthy provider life, protected and has isolation functions simplify low-voltage control circuit, increase the reliability of the automation management method, supplying a reliable simple component for minimal-voltage power distribution and motor management circuits.
RDCPS2 is topic to IEC60947-1, EC60947-six-two specifications.
The supplies used in this merchandise comply with the demands of the ROHS Directive (guide Pb, mercury Hg, cadmium Cd, hexavalent chromium Cr, polybrominated biphenyl PBBs, polybrominated diphenyl ether PBTEs, and so forth.)
Working Problems
CZPT Doing work Setting
Ambient temperature:from -15ºC to+40ºC,24h common temperature ≤ +35ºC
Set up altitude: ≤ 2000m
Set up surroundings humidity:When the optimum temperature is +forty °C, the relative humidity of the air does not exceed 50%, greater relative humidity is authorized at decrease temperatures, for illustration, ninety% at +20 °C, for temperature modifications Specific measures should be taken for occasional condensation
Environmental pollution amount: Course three
Protection level: IP20
Relevant electromagnetic environment: Course A
WARNING: This solution is supposed for use in Setting A. Use of this merchandise in Setting B can lead to dangerous electromagnetic interference, in which situation the person should just take proper safeguards.
Storage and transportation circumstances
Storage and transportation surroundings of the solution ought to be cool and ventilated. There ought to be no direct sunlight, rain forest, dust, chemical fuel corrosion, etc. The relevant ambient temperature range is -25°C~ +55°C, and it can achieve +70°C in a brief time (24h)
Installation problems
Major circuit overvoltage group of this change is relevant to III (distribution stage), and the auxiliary circuit and manage circuit overvoltage classification is relevant to II (load amount).
Utilization Category
RDCPS2 manage and protective swap applies to underneath load circuits. | ||
Circuit | Utilization Classification | Software |
Principal Circuit | AC-20 | Producing/breaking CZPT load |
AC-40 | Distribution circuit, which includes mixed resistivity and inductive load | |
AC-forty one | AC-42No-inductive or micro inductive load, resistor furnace | |
AC-forty two | Slip ring variety motor: start off, breaking | |
AC-43 | Cage sort inductive motor: start off, breaking during working | |
AC-forty four | Cage sort inductive motor: commence, reverse connect cease or reverse operating, level shifting. |
|
AC-45a | Discharge lamp ON/OFF | |
AC-45b | Filament lamp ON/OFF | |
Auxiliary Circuit | AC-fifteen | Management AC electric powered magnet |
DC-13 | Manage DC electric powered magnet load |
CZPT Info
Primary complex datas (principal circuits) | ||||||
Frame dimension | 63 | a hundred twenty five | ||||
Rated doing work voltage Ue | 400VAC/690VAC(220VAC customized style) | |||||
Rated isolation voltage Ui | 690V | 800V | ||||
Rated face up to voltage Uimp | 6kV | 8kV | ||||
Traditional thermal recent Ith(A) | twelve | 32 | sixty three | eighty | one hundred twenty five | |
Rated doing work recent Ie(A) | .6, one.2, 2.4,six,twelve | 18, 32 | forty five,sixty three | 80 | 125 | |
Rated frequency | 50Hz(60Hz customized style) | |||||
Rated operational technique (Intermittent duty) | three hundred | one hundred twenty | ||||
Rated short-circuit breaking capacity Ics | AC400V | 50kA | 50kA | |||
AC690V | 4kA | 6kA | ||||
Utilization Classification | AC-43 | |||||
Breaking action time | ≤ 2ms | |||||
Amount of poles | 3 |
Primary complex datas(Rated doing work current and handle energy) | ||||||
Frame dimensions | Conventional thermal current Ie(A) | Rated working recent Ie(A) |
Overload current placing selection Ir1(A) |
Controllable motor energy Pe(kW) | ||
220VAC | 400VAC | 690VAC | ||||
63 | 12 | .six | .fifteen-.6 | .04-.eighteen | .01-.eighteen | .07-.three |
1.two | .three-1.2 | .06-.18 | .07-.five | .13-.86 | ||
2.4 | .six-two.4 | .09-.55 | .fifteen-one. | .twenty five-1.eight | ||
6 | 1.five-6 | .25-1.five | .52-2.eight | .9-five. | ||
12 | 3-12 | .seventy five-three | 1.1-six | two.-10 | ||
32 | eighteen | seven.2-eighteen | 1.five-4 | 3.-9.five | 5.-sixteen | |
32 | 12-32 | three-7.five | five.-16.five | eight.5-29 | ||
sixty three | forty five | eighteen-forty five | 4-eleven | 7.one-23.5 | fourteen-forty three | |
63 | 25-sixty three | 5.five-eighteen.five | ten-35 | 19-60 | ||
125 | eighty | 80 | forty five-80 | eleven-22 | twenty-forty five | 36-76 |
one hundred twenty five | 125 | 63-125 | 19.5-37 | 28-55 | fifty one-a hundred and ten |
Main complex datas(management and auxiliary circuit) | ||||
Body measurement rated functioning current Inm(A) | sixty three | 125 | ||
Manage Circuit | Control voltage Us(V) | 230VAC 50Hz(60Hz customized design) | ||
Electromagnet coil’s Max. electrical power consumption(W) | four | seven | ||
Electromagnet coil’s action time(ms) | generating: significantly less than 80, breaking: less than 70 | |||
Mechanical daily life (cycles) | ten milion | 3 milion | ||
CZPTal life(AC-forty three) ( cycles) | one milion | three hundred,000 | ||
Operation frequency(on-load issue forty%) | 600 | 600 | ||
Auxiliary swap circuit | Quantity of contacts | 2NO + 2NC | 2NO + 2NC | |
Speak to potential | AC-fifteen | 230VAC, 5A | ||
DC-13 | ( DC110V,..55A), (DC24V, 5A) | |||
Ui:250V,Uimp:4kV,Ith:5A | ||||
Auxiliary position circuit | Number of contacts | 2NO + 1NC | 2NO + 1NC | |
Ue:230VAC ,Ui:250V,Uimp:4kV,Ith:5A | ||||
Controller alarm circuit | Amount of output contacts | 1NO | 1NO | |
Ue:230VAC ,Ui:250V,Uimp:4kV,Ith:5A | ||||
Communication circuit module | Ue:24VDC ,Ui:24V,Uimp:.8kV |
Dlivery Conditions
Shipment & Express & Air express
Packing
About the Firm
RADIN areas are TUV, CE, CB, RoHS certified, and the manufacturing facility is iso9001:2015 experienced.
FAQ:
one. What is the guarantee phrase?
24 Monthes.
two. How extended does it consider to provide my merchandise?
Generally, samples can be shipped in 2 days. CZPTer designed sampleswill be sent in 3-7 times.
3. Do you offer sample?
Indeed, we provide sample order for client to test the items.
four. What varieties of payment conditions do you take?
We offer you kinds of payment ways foe consumer to chose from. T/T, L/C, Aliexpress, Western union and many others.
five. What if there is certainly top quality peoblem?
We offer you replacement for the products as quickly as there is a quality issue with the merchandise, and the fright is on our account to reduce down the customer’s loss to the cheapest.
We are confident any of your inquiries will get our prompt reply, just go away the information!