Solution Description
Attributes
M-driver M550 VS M300 collection
1. IGBT module
M550 use Infineon IGBT module from 11kw , Chinese brand IGBT module from .75kw to 7.5kw.
M300 use Chinese brand IGBT module from .75kw to 37kw.
two. Terminals
Simplified terminals for M300 collection
For M300, 3 electronic inputs, 1 analong enter and 1 relay ouput, No digital ouputs and or analog outputs , no created-in brake device, RS485 is opitonal.
Profound terminals for M550 collection
For M550, 5 digital inputs, 2 digital inputs, 2 digital outputs , 2 relay outputs and 2 analog outputs, created-in brake device for .75kw to 22kw, RS485 is regular.
three. Price tag
M300 is much more reasonably priced
4. Warranty
The warranty is the identical. We offer eighteen months warranty.
Item Description
Product | Specifications | |
Fundamental perform | Over load functionality | G type:a hundred and fifty% rated current 60s180% rated current 3s |
P type:one hundred twenty% rated current 60s150% rated current 3s | ||
Torque enhance | Car torque enhance perform Handbook torque boost 0.1%~thirty.% | |
V/F curve | Linear V/F, multi-position V/F and square V/F curve(electricity of 1.2,1.4,1.6,1.8,2) | |
V/F separation | 2 ways: separation and semi-separation | |
Acc./dec curve | Straight line or S curve acceleration and deceleration manner, | |
4 types of acceleration and deceleration time. Acceleration and deceleration time range from .0s to 6500.0s | ||
DC braking | DC braking frequency:.00Hz to greatest frequency. Braking time:.0s to 36.0s | |
Brake present price:%-100% | ||
Jog management | Jog frequency assortment:.00Hz~fifty.00Hz | |
Jog acceleration/deceleration:.0s~6500.0s. | ||
Simple PLC | It can recognize at optimum of sixteen segments pace | |
Basic operate | Multiple segment velocity operating | Managing via the created-in PLC or manage terminal. |
Created-in PID | It is easy to realize approach-controlled closed loop handle system. | |
Automobile voltage regulation (AVR) | It can maintain continuous output voltage routinely in the situation of change of network voltage. | |
Above-voltage/recent stall manage | It can restrict the working voltage/present automatically and avert recurrent in excess of-voltage/present tripping throughout the operating process. | |
Rapid present restrict | Reduce the above-existing fault, defend typical operation of the AC CZPT . | |
Torque limit & manage | “Excavators” characteristics, instantly restrict torque throughout operation, avert regular in excess of-recent tripping. Closed loop vector mode can understand the torque manage. | |
Personalized function | Instantaneous cease CZPT -quit | When instantaneous CZPT off, voltage reduction is compensated through load comments power, which could make AC CZPT maintain running in a brief time period of time. |
Quick current restrict | To keep away from AC CZPT repeated above-present fault. | |
Timing manage | Timing control function:established time selection 0Min~6500.0Min. | |
Operating | Command source | Procedure panel reference, control terminal reference and serial conversation port reference. These channels can be switched in CZPT modes. |
Frequency resource | There are entirely eleven types of frequency resources, these kinds of as digital reference, analog voltage reference , analog present reference, pulse reference, MS velocity, PLC, PID and serial port reference. | |
Input terminal | 3 digital input terminals. | |
1 analog input | ||
1 supporting -10V voltage input or ~20mA present enter terminal. | ||
Output terminal | ||
1 relay output terminals. | ||
Keyboard procedure | Keyboard potentiometer | Geared up with keyboard potentiometer or coding potentiometer. |
Keyboard operation | Protection function | It can employ CZPT -on motor brief-circuit detection, enter /output phase loss defense, above existing security, more than voltage safety, underneath voltage security, overheating security and overload safety. |
Environment | Employing spot | Indoor, and be free of charge from immediate sunlight, dust, corrosive gas, combustible gas, oil smoke, vapor, drip or salt. |
Altitude | Under 1000m | |
Ambient temperature | -10 ºC to +40 ºC (Derating use when under ambient temperature of 40 ºC to 50 ºC) | |
Humidity | Much less than ninety five%RH,without condensing | |
Vibration | Much less than 5.9m/s (.6g) |
Item Parameters
Type | Travel motor | Electricity capacity | Input recent | Output recent | Dimension(mm) |
KW | KVA | A | A | ||
Single period CZPT provide: 220V, 50/60A | |||||
M300-C0007G1 | .75 | 1 | 4.two | 4 |
152*101*117 |
M300-C0015G1 | one.5 | two | fourteen | seven |
152*one zero one*117 |
M300-C0571G1 | 2.two | three | 23 | 10 |
152*one zero one*117 |
Three section CZPT offer 220V ,fifty/60hz |
M300-C0040G2 | four | 5 | eighteen.one | 16 |
221.6*113*167 |
M300-C0055G2 | 5.five | 7.five | 28 | twenty five |
265*one hundred sixty*171.5 |
M300-C0075G2 | 7.5 | ten | 37.1 | 32 |
265*160*171.5 |
M300-C0110G2 | eleven | fifteen | forty nine.8 | forty five |
303*192*171.five |
M300-C0150G2 | 15 | twenty | 65.four | 60 |
349*227*171.five |
M300-C0185G2 | 18.five | 25 | eighty one.6 | 75 |
349*227*171.five |
M300-C5710G2 | 22 | 30 | 97.7 | 90 |
490*330*217 |
M300-C0300G2 | thirty | forty | 122.1 | one hundred ten |
490*330*217 |
M300-C571G2 | 37 | fifty | 157 | a hundred and fifty |
600*387*280 |
M300-C0450G2 | 45 | 60 | 185 | one hundred seventy |
600*387*280 |
M300-C 0571 G2 | 55 | 70 | 215 | 210 |
690*370*350 |
M300-C571G2 | seventy five | 100 | 320 | three hundred |
849*480*389 |
Three section CZPT offer: 380V ,50/60hz | |||||
M300-C0007G3 | .75 | one | 3.four | 2.one | 152*one hundred and one*117 |
M300-C0015G3 | one.5 | two | five | 3.eight | 152*a hundred and one*117 |
M300-C0571G3 | two.2 | three | five.eight | 5 | 152*one zero one*117 |
M300-C0040G3 | four | 5 | 10.five | nine |
221.6*113*166.5 |
M300-C0055G3 | 5.5 | 7.five | 14.6 | 13 |
221.6*113*166.5 |
M300-C0075G3 | seven.5 | 10 | 20.five | seventeen |
221.6*113*166.five |
M300-C0110G3 | 11 | fifteen | 26 | twenty five |
265*one hundred sixty*171.five |
M300-C0150G3 | 15 | twenty | 35 | 32 |
265*one hundred sixty*171.five |
M300-C0185G3 | eighteen.5 | twenty five | 38.five | 38 |
302.5*192*171.5 |
M300-C5710G3 | 22 | 30 | forty six.five | 45 |
302.5*192*171.five |
M300-C0300G3 | 30 | forty | sixty two | 60 |
348.5*227*171.5 |
M300-C571G3 | 37 | 50 | seventy six | seventy five |
348.5*227*171.five |
Thorough Pictures
Certifications
Packaging & CZPT
Organization Profile
FAQ
Q 1: Are you investing firm or maker ?
We are factory.
Q 2: How CZPT is your lead time?
Generally 3-7 days if the items are in inventory, or 10-20 times if the stocks are not sufficient, it is according to amount.
Q 3: Do you provide samples ? is it totally free or added ?
Sure, we give samples and demand for the samples with freight price. The sample fees will be returned if the order quantity more than 500pcs.
Q 4: What is your terms of payment ?
We accept T/T(thirty% deposit, 70% equilibrium), L/C and CZPT .
Q 5: What is the standard of package deal?
One little carton or plywood crate.
Q 6. Is there any price reduction ?
The price reduction will count on the quanlity you buy.
Q 7. What is your offer potential?
The daily creation is 2000pcs.
Q 8. Do you offer guarantee for the merchandise?
Of course, we supply 18 months warranty for all the items.
Q 9. Could M-driver supply technological support?
Yes, we worked 19 years in this field and have a whole lot of seasoned engineers, they will supply options if get a issue.
Induction motors, also recognized as asynchronous motors, use the electromagnetic induction generated by the magnetic area of the stator to make current in the rotor, therefore producing torque. These motors do not run at a pace in sync with the recent, therefore the identify. They use the phenomenon of electromagnetic induction to transform electrical energy into mechanical power. Induction motor rotors are the most typical type of AC motor located in pumps, compressors, and other equipment of all varieties.